压接工艺是检验线束厂的技术能力的重要考量,本文主要线束压接工艺的技术参数及要求。
1.一般压接后技术要求(无特殊规定)
一般压接后技术要求(无特殊规定)如图4-34所示,具体内容如下:文章源自线束工程师之家-https://www.suncve.com/technical-parameters-and-requirements-of-wire-harness-crimping-technology/
文章源自线束工程师之家-https://www.suncve.com/technical-parameters-and-requirements-of-wire-harness-crimping-technology/
(1)端子压接后的线芯出头长度最佳状态ab为0.2m~1.0m。文章源自线束工程师之家-https://www.suncve.com/technical-parameters-and-requirements-of-wire-harness-crimping-technology/
(2)前料带切断长度为0~0.3mm。文章源自线束工程师之家-https://www.suncve.com/technical-parameters-and-requirements-of-wire-harness-crimping-technology/
(3)后料带切断长度为0~0.5mm。文章源自线束工程师之家-https://www.suncve.com/technical-parameters-and-requirements-of-wire-harness-crimping-technology/
(4)前后R角的半径为0.4m~1.0m,或至少有一个后R角半径为0.4m-0.6mm。文章源自线束工程师之家-https://www.suncve.com/technical-parameters-and-requirements-of-wire-harness-crimping-technology/
(5)压接高度和宽度的符合工艺要求。文章源自线束工程师之家-https://www.suncve.com/technical-parameters-and-requirements-of-wire-harness-crimping-technology/
(6)拉脱力符合工艺要求。文章源自线束工程师之家-https://www.suncve.com/technical-parameters-and-requirements-of-wire-harness-crimping-technology/
(7)压接类型符合工艺要求。文章源自线束工程师之家-https://www.suncve.com/technical-parameters-and-requirements-of-wire-harness-crimping-technology/
(8)绝缘层压接部位经不少于3个循环的弯折试验后,线皮的最佳状态是cd=de,ce间仍可见绝缘层。文章源自线束工程师之家-https://www.suncve.com/technical-parameters-and-requirements-of-wire-harness-crimping-technology/
2.绝缘压接区及防水栓部位的压接和检测
绝缘压接区及防水栓部位的压接要求和检测应符合《汽车电线束技术条件》(QC/T 29106)的要求:
①防水栓完好无损。
②最佳状态为线皮可见,至少线皮和防水栓边缘平齐。
③防水栓可见。
④线芯可见。
⑤防水栓经过至少3个弯折循环后未脱出。
⑥线芯出头的范围是0.2mm~1.0mm。
⑦导体压接部两端可见R角。
3.电线接点处U型端子压接参数和检测
应符合《汽车电线束技术条件》(QC/T 29106)的要求。压接时钳口的压接点应垂直在U型卡的中间,且剥皮长度应相同,位置对正。
①线芯可见,最大为3mm。
②两端可见R角。
③线芯完好无损,压着部分无遗漏。
④线芯可见,最小为1mm,最大为5mm。