高压导线应遵循SAE J1654、SAE J1673规定的要求。在此基础上,需要结合如下因素,明确高压导线的线径选型。

(1) 导线线径选型需满足LV216-1/2、ISO19642等标准。文章源自线束工程师之家-https://www.suncve.com/selection-method-of-wire-diameter-for-high-voltage-wire/

(2) 确定高压线束所连接的电气部件的负载特性,包括稳态电流强度、电压要求、瞬态条件和电流强度及电流波形(平稳、脉冲、频率等)。文章源自线束工程师之家-https://www.suncve.com/selection-method-of-wire-diameter-for-high-voltage-wire/

(3) 根据稳态电流强度,确定导线的截面积文章源自线束工程师之家-https://www.suncve.com/selection-method-of-wire-diameter-for-high-voltage-wire/

电流强度及截面积计算公式如下:文章源自线束工程师之家-https://www.suncve.com/selection-method-of-wire-diameter-for-high-voltage-wire/

用电设备的电流强度为:I=P/U(*P为负载功率,*U为额定电压)文章源自线束工程师之家-https://www.suncve.com/selection-method-of-wire-diameter-for-high-voltage-wire/

导线截面积计算公式为:A=IρL/UVL(*A为导线截面,*I为电流值,*ρ为铜导线电阻率,*L为导线长度,*UVL—导线允许的电压降)文章源自线束工程师之家-https://www.suncve.com/selection-method-of-wire-diameter-for-high-voltage-wire/

电流密度S=I/A(*I为电流强度,*A为导线截面),通过检查电流密度来避免导线过渡发热。文章源自线束工程师之家-https://www.suncve.com/selection-method-of-wire-diameter-for-high-voltage-wire/

(4) 根据工作环境温度,对导线截面积进行调整文章源自线束工程师之家-https://www.suncve.com/selection-method-of-wire-diameter-for-high-voltage-wire/

高压导线的工作温度在-40℃~125℃,需要通过AC2500V/min,50Hz的耐电压测试。文章源自线束工程师之家-https://www.suncve.com/selection-method-of-wire-diameter-for-high-voltage-wire/

如果高压导线的布置环境超过了导线允许的工作温度,则必须选择较大截面积的导线,当环境温度最高为180℃时,导体截面积上升一档使用;当环境温度最高为250℃时,导体截面积上升两档使用。文章源自线束工程师之家-https://www.suncve.com/selection-method-of-wire-diameter-for-high-voltage-wire/

举例:当最大电流为150A时,在125℃情况下,使用35mm²的高压线束;在180℃情况下,选用50mm²线束;在250℃情况下,选用70mm²的高压线束。